STAND ALONE UPS SYSTEMS

MODULAR UPS SYSTEMS

BATTERIES & RECTIFIERS


CONTACT US


Product Overviews



High Rate Max XT Series



Valve Regulated Lead Acid (VRLA)

- Design life:10 years
- 3 years warranty
- For UPS Standby Power Applications

High Rate Max



Features






- Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance
- Patented Long Life Alloy having the lowest calcium levels in the industry-minimizing grid growth, reducing gassing, and extending battery life
- Patented UL Recognized Flame-arresting vents in each cell for safety and long life
- Designed with the same recombination, thermal runaway prevention, gassing and flame retardant characteristics of the Bellcore 4228 compliant Dynasty Telecom products
- Flame retardant polypropylene case and cover compliant with UL94-V2
- Proprietary Fixed Orifice Plate Pasting technology applying active materials on both sides of the grid for consistent cell-to-cell performance, higher capacity and uniform grid protection
- Thermally welded case-to-cover bond to eliminate leakage
- Can be operated in any orientation. Upright, side or end mounting recommended
- Not restricted for air transport - Complies with IATA/ICAO Special Provisions A67
- Not restricted for surface transport-Classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189
- Not restricted for water transport-Classified as non-hazardous material per IMDG Amendment 27


Specifications




Model
V
Watts/Cel @ 15minl
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
UPS 12-100 MRX
12
100
197
132 166 173 10.7 Insert (#10-32 UNF)
UPS 12-130 MRX
12
130
197
132 166 173 11.5 Insert (#10-32 UNF)
UPS 12-150 MRX
12
150
197
132 166 173 12.4 Insert (#10-32 UNF)
UPS 12-200 MRX
12
200
229
139 200 205 17.7 Insert (#10-32 UNF)
UPS 12-220 MRX
12
220
229
139 200 205 19.0 Insert (#10-32 UNF)
UPS 12-280R MRX
12
280
273
174 201 204 25.7 Insert (1/4-20 UNC)
UPS 12-320R MRX
12
320
273
174 201 204 27.0 Insert (1/4-20 UNC)
UPS 12-370R MRX
12
370
319
173 203 205 31.5 Insert (1/4-20 UNC)
UPS 12-400 MRX
12
400
341
173 213 216 35.3 Insert (1/4-20 UNC)
UPS 12-440 MRX
12
440
341
173 213 216 36.0 Insert (1/4-20 UNC)
UPS 12-475 MRX
12
475
341
173 213 216 38.0 Insert (1/4-20 UNC)
UPS 12-490 MRX
12
490
345
173 275 278 46.6 Insert (1/4-20 UNC)
UPS 12-520 MRX
12
520
345
173 275 278 47.2 Insert (1/4-20 UNC)
UPS 12-550 MRX
12
550
345
173 275 278 48.6 Insert (1/4-20 UNC)
UPS 12-600 MRX
12
600
345
173 275 278 49.4 Insert (1/4-20 UNC)



True Front Access battery (high power rate)





- True Front Access threaded copper alloy inserts, for reduced maintenance and increased safety
- Terminal versatility - ease of diagnostic readings with C&D Ohmic Ring®
- Innovative front terminal design maximizing energy density with direct connect extrusion fusionweld technology
- Reduced headspace driving higher energy density, in cabinet or rack applications
- Removable handles for ease of installation
- Thermally welded case-to-cover bond to ensure a leak-proof seal
- Flame-retardant polypropylene case and cover compliant with UL94 V-0 with an Oxygen Limiting Index of greater than 28
- Absorbent Glass Mat (AGM) technology for efficient gas recombination of over 99%
- Flame-arresting, one-way pressure-relief vent for safety and long life - Complies with UL 1778,924,1989 and 94 V-0. BS6290-4, IEC60896
- Multicell design for ease of installation and maintenance
True Font Access


Specifications



Model
V
Watts/Cel @ 15minl
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
UPS 12-410 MRXF
12
410
498
108
215
231
37.1
Insert (M6)
UPS 12-615 MRXF
12
615
547
123
269
278
55.2
Insert (M8)
UPS 12-700 MRXF
12
700
547
123
310
322
64.9
Insert (M8)


MPS Series




Valve Regulated Lead Acid (VRLA)

• Design life: 5 years(≤26Ah)
10 years(>26Ah)
• For UPS,Telecom,Utility

Features

- Robust plate for extended life
- Flame-arresting one-way pressure-relief vent for safety and long life
- Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance
- UL-recognition component
- Multicell design for cost effective installation and maintenance
- Can be used in upright, side, or end mounting orientation
- Not restricted for air transport Compiles with IATA/ICAO Special Provision
- Not restricted for surface transport classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189
- Not restricted to water transport classified as non-hazardous material per IMDG Amendment 27
- Computer designed lead , low Calcium alloy grid for minimal gassing and ease of recycling
Multi-Purpose


Specifications




Model
V
Watts/Cel @ 15minl
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
MPS 12-7A
12
7
151
65
94
100
2.2
Faston Tab 187/250
MPS 12-9A
12
9
151
65
94
100
2.6
Faston Tab 187/250
MPS 12-12A
12
12
151
98
95
101
3.6
Faston Tab 187/250
MPS 12-18A
12
18
181
77
166
166
5.0
Insert (M5)
MPS 12-26A
12
26
166
175
125
125
8.1
Insert (M5)
MPS 12-40A
12
40
198
166
171
171
13.2
Insert (M6)
MPS 12-54
12
54
228
139
201
225
17.0
L-type (M6)
MPS 12-65R
12
65
273
174
201
224
21.0
L-type (M6)
MPS 12-76R
12
76
273
174
201
224
23.3
L-type (M6)
MPS 12-88R
12
88
319
173
203
230
25.5
L-type (M6)
MPS 12-100R
12
100
319
173
203
230
29.0
L-type (M6)
MPS 12-114
12
114
341
173
213
241
32.5
L-type (M6)
MPS 12-127A
12
127
407
177
225
225
35.0
Insert (M8)
MPS 12-158A
12
158
483
170
241
241
44.5
Insert (M8)
MPS 12-211A
12
211
522
239
218
223
60.0
Insert (M8)
MPS 12-242A
12
242
521
269
203
208
67.0
Insert (M8)


DNTY Series




Valve Regulated Lead Acid (VRLA)

• Design life:12 years(models above 12-100 DNT)
• For UPS Applications

Features :

- Lead Calcium Alloy Grids - Lowest Level of Calcium among manufacturers, which reduces grid corrosion

- Radial grid design provides the most efficient power pathway to transfer power from the active material to the terminal

- Patend Long Life Alloy having the lowest calcium levels in the industry , minimizing grid growth , reducing gassing, and extending battery life

- Absorbtion Glass Mat (AGM) technology fo efficient gas recombination of up to 99% and freedom from electrolyte maintenance

- Propietary Fixed Orifice Pasting Technology - More consistent pasting process where paste is applied to both sides of the plate to reduce riskof shorts.

- Patented UL Recognized Flame-arresting vents in each cell for safety and long life.

- Designed with the same rrecombination , thermal runaway prevetion ,gassing and flame retardent characteristics of the Bellcore 4228

- Can be used in upright , side, or end mounting orientation


LBTY - 2V Series



Valve Regulated Lead Acid

- Design life :10 years

- 3 years Warranty

- For Telecom , UPS, Utility

Features

- High quality design insurance
- Pb-Ca Alloy for positive plate grid
- Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance
- Lower self-discharge rate (about 3% per month @20°C)
- UL-recognized component
- Flame retardant container materials, complied with materials UL94-HB,
- UL94-V0 Optional
- Not restricted for air transport – Complies with IATA/ICAO Special
- Provisions A67
- Not restricted for surface transport – Classified as non-hazardous
- material as related to DOT-CFR 49 Title 49 parts 171-189
- Not restricted for water transport – Classified as non-hazardous material per IMDG Amendment 27

LBTY - 2V Series

Specifications



Model
V

Capacity /Ah
(C10,1.80v@25°c

Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
C&D 12-25A DNT
12
28
151
65
94
100
2.2
Faston Tab 250
C&D 12-65A DNT
12
72
181
77
166
166
5.6
Insert (M5)
C&D 12-100 DNT
12
100
197
132
166
173
10.7
Insert (#10-32 UNF)
C&D 12-130 DNT
12
130
197
132
166
173
11.5
Insert (#10-32 UNF)
C&D 12-150 DNT
12
150
197
132
166
173
12.4
Insert (#10-32 UNF)
C&D 12-200 DNT
12
200
229
139
200
205
17.7
Insert (#10-32 UNF)
C&D 12-220 DNT
12
220
229
139
200
205
19.0
Insert (#10-32 UNF)
C&D 12-280 DNT
12
280
273
174
201
204
25.7
Insert (1/4-20 UNC)
C&D 12-320 DNT
12
320
273
174
201
204
27.0
Insert (1/4-20 UNC)
C&D 12-370 DNT
12
370
319
173
203
205
31.5
Insert (1/4-20 UNC)
C&D 12-400 DNT
12
400
341
173
213
216
35.3
Insert (1/4-20 UNC)
C&D 12-440 DNT
12
440
341
173
213
216
36.0
Insert (1/4-20 UNC)
C&D 12-475 DNT
12
475
341
173
213
216
38.0
Insert (1/4-20 UNC)
C&D 12-490 DNT
12
490
345
173
275
278
46.6
Insert (1/4-20 UNC)
C&D 12-520 DNT
12
520
345
173
275
278
47.2
Insert (1/4-20 UNC)
C&D 12-550 DNT
12
550
345
173
275
278
48.6
Insert (1/4-20 UNC)
C&D 12-600 DNT
12
600
345
173
275
278
49.4
Insert (1/4-20 UNC)
C&D 12-675A DNT
12
692
522
239
218
223
65.0
Insert (M8)
C&D 12-775A DNT
12
785
522
239
218
223
75.5
Insert (M8)
C&D 6-630A DNT
12
630
260
171
220
224
28.8
Insert (M8)


TEL-TFA Series




Valve Regulated Lead Acid (VRLA)

• Design life: 10 years
• For Telecom, Utility Applications

Features

- Long life alloy and over 10+ years design life (at 25ºC)
- Tested and qualified by Telecordia to meet SR-4228 requirements
- True Front Access threaded copper alloy inserts for reduced maintenance and increased safety
- Terminal versatility - ease of diagnostic readings with C&D Ohmic Ring®
- Reduced headspace driving higher energy density, in cabinet or rack
applications
- Removable handles for ease of installation
- Innovative front terminal design maximizing energy density with direct
connect extrusion fusion weld technology
- Thermally welded case to cover bond to ensure a leak-proof seal
- Flame-retardant polypropylene case and cover compliant with UL94 V-2
- Absorbent Glass Mat (AGM) technology for efficient gas recombination
of over 99%
- Flame-arresting, one-way pressure-relief vent for safety and long life
- UL recognized components
- Complies with UL 1778, 924, 1989 and 94 V-2, BS6290-4, IEC60896
- Can be used in upside, side or end mounting orientation
- Multicell design for ease of installation and maintenance
- Not restricted for air transport -Complies with IATA/ICAO Special
Provisions A67
- Not restricted for surface transport -Classified as non-hazardous
material as related to DOT-CFR Title 49 parts171-189
- Not restricted for water transport -Classified as non-hazardous material
per IMDG Amendment 27

Tel-TFA Series


Specifications


Model
V
Capacity /Ah
(C10,1.80v@25°c
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
C&D 2-200LBT
2
200
170
106
330
345
12.4
Insert (M10)
C&D 2-300LBT
2
300
170
150
330
345
17.8
Insert (M10)
C&D 2-400LBT
2
400
196
171
330
345
23.6
Insert (M10)
C&D 2-500LBT
2
500
241
171
330
345
29.3
Insert (M10)
C&D 2-600LBT
2
600
286
171
330
345
35.2
Insert (M10)
C&D 2-800LBT
2
800
383
171
330
345
47.1
Insert (M10)
C&D 2-1000LBT
2
1000
471
171
330
345
58.8
Insert (M10)
C&D 2-1500LBT
2
1500
476
337
330
345
92.0
Insert (M10)
C&D 2-2000LBT
2
2000
476
337
330
345
117.0
Insert (M10)
C&D 2-2500LBT
2
2500
696
340
330
345
161.0
Insert (M10)
C&D 2-3000LBT
2
3000
696
340
330
345
185.0
Insert (M10)

 

TEL-FG Series



Valve Regulated Lead Acid (VRLA)
- Design life: 13 years
- For Telecom Standby Power Applications

Features
- Long life alloy and 13 years design life
- Standard gas collection system for telecom. sealed cabinet installation
- Tested and qualified by Telecordia to meet SR-4228 requirements
- True Front Access threaded copper alloy inserts for reduced maintenance
and increased safety
- Terminal versatility - ease of diagnostic readings with C&D Ohmic Ring®
- Reduced headspace driving higher energy density, in cabinet or rack applications
- Removable handles for ease of installation
- Innovative front terminal design maximizing energy density with direct
connect extrusion fusion weld technology
- Thermally welded case to cover bond to ensure a leak-proof seal
- Flame-retardant polypropylene case and cover compliant with UL94 V-0
with an Oxygen Limiting Index of greater than 28
- Absorbent Glass Mat (AGM) technology for efficient gas recombination
of over 99%
- Flame-arresting, one-way pressure-relief vent for safety and long life
- Complies with UL 1778, 924, 1989 and 94 V-0, BS6290-4, IEC60896
- UL recognized components
- Can be used in upside, side or end mounting orientation
- Multicell design for ease of installation and maintenance
- Not restricted for air transport -Complies with IATA/ICAO Special
Provisions A67
- Not restricted for surface transport -Classified as non-hazardous
material as related to DOT-CFR Title 49 parts171-189
- Not restricted for water transport -Classified as non-hazardous material
per IMDG Amendment 27

Tel - FG Series


Specifications


Model
V
Capacity /Ah
(C10,1.80v@25°c
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
TEL 12-105FNSG
12
100
410
107
267
289
33.0
Insert (M8)
TEL 12-115FNG
12
104
511
110
215
237
33.5
Insert (M6)
TEL 12-155FG
12
148
559
126
269
285
48.3
Insert (M8)
TEL 12-170FG
12
162
559
126
269
285
49.5
Insert (M8)
TEL 12-190FG
12
183
559
126
310
328
57.7
Insert (M8)
TEL 12-210FG
12
195
559
126
310
328
61.2
Insert (M8)

 

TEL-FGC Series



TEL-FGC Series
• Design life: 10 years
• For Unstable Grid, Renewable Energy Applications

Features

Long life cycle service design:
- Proven C&D DCS plate technology
- Maximum cycle life for deep cycle & hybrid applications
- High charge acceptance for rapid recharge
True front access design:
- True direct connect terminal for reliabiliaty
V C&D Ohmic Ring for accurate testing
- Standard true front access gas collection system for sealed cabinet
installation
- Connection versatility
The best electric property:
- Superior output due to direct terminal connection
- Low internal resistance
Valve Regulated Lead Acid (VRLA)

Compliant to major global specifications:

- British Standard BS 6290: Part 4:1997
- IEC 60896-21/22
- Telecordia SR-4228
- Eurobat Guide Classification: long life
- Bellcore GR-63-CORE & GR-1089-Core
- UL94 V-0 FR
- Non-hazardous, not restricted for any transportation mode (air, water
or land)

TEL-FGC Series


GEL Series




Design life:

18 years(2V)
12 years(12V)

- For UPS, Telecom, Utility, Renewable Energy Applications
Valve Regulated Lead Acid (VRLA)- GEL Type

Features

- Gel electrolyte technology for better wide temperature range performance, prevention from thermal runaway, insure reliability and safety
- Proprietary Pb-Ca Alloy – minimizing grid growth, reducing gassing, and extending battery life
- Flame arresting one-way pressure vents for safety and improved life
- Gas recombination efficiency of up to 99% for freedom from electrolyte maintenance
- Good deep cycle performance
- Lower self-discharge rate (Less than 3% per month)
- Not restricted for air transport – Complies with IATA/ICAO Special Provision A67
- Not restricted for surface transport – classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189
- Not restricted for water transport – classified as non-hazardous material per IMDG Amendment 27

GEL-Series

 

Specifications


Model
V
Capacity /Ah
(C10,1.80v@20°c
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
C&D 2-100 GEL
2
133
172
102
206
227
8.0
Insert (M8)
C&D 2-150 GEL
2
178
173
110
330
366
14.0
Insert (M8)
C&D 2-200 GEL
2
222
171
150
330
366
17.5
Insert (M8)
C&D 2-300 GEL
2
311
211
176
330
366
24.5
Insert (M8)
C&D 2-400 GEL
2
400
242
172
330
366
29.0
Insert (M8)
C&D 2-500 GEL
2
533
302
175
330
366
37.0
Insert (M8)
C&D 2-600 GEL
2
666
410
175
330
367
46.0
Insert (M8)
C&D 2-800 GEL
2
888
475
174
330
366
62.0
Insert (M8)
C&D 2-1000 GEL
2
1066
475
174
330
366
76.0
Insert (M8)
C&D 2-1200 GEL
2
1332
401
350
341
383
96.0
Insert (M8)
C&D 2-1500 GEL
2
1776
490
350
343
383
126.5
Insert (M8)
C&D 2-2000 GEL
2
2221
710
352
340
383
171.0
Insert (M8)
C&D 2-2500 GEL
2
2665
710
352
340
383
193.0
Insert (M8)
C&D 12-20 GEL
12
23
166
175
125
125
8.2
Insert (M8)
C&D 12-40 GEL
12
49
229
138
210
216
18.0
Insert (M8)
C&D 12-50 GEL
12
50
260
169
211
216
20.5
Insert (M8)
C&D 12-65 GEL
12
67
260
169
211
216
23.5
Insert (M8)
C&D 12-90 GEL
12
90
328
172
215
222
30.0
Insert (M8)
C&D 12-100 GEL
12
106
407
177
225
225
35.0
Insert (M8)
C&D 12-120 GEL
12
119
341
173
281
288
41.5
Insert (M8)
C&D 12-150 GEL
12
160
530
209
214
219
53.0
Insert (M8)
C&D 12-180 GEL
12
177
522
239
218
223
60.0
Insert (M8)
C&D 12-200 GEL
12
204
521
269
203
208
67.0
Insert (M8)
C&D 12-230 GEL
12
231
520
268
220
225
74.0
Insert (M8)

 

LIBERTY® 1000 SERIES


Valve Regulated Lead Acid (VRLA)

- 10 years life battery
- 1+9 years pro-rate warranty
- For Telecom, Switchgear Utility, UPS Aplications

Features

- Patented C&D post seal design with secondary epoxy to increase integrity
- Two-fold vent system, Minimizes bulging, and Prevents flashback explosion from external ignition source
- Thick radial grid design , improves current carrying capacity andperformance, insure Long float life
- Immobilized electrolyte technology , Absorbent glass mat design (AGM), for Safe handling and storage
- Advanced, computer-controlled thermal cover-to-jar weld, ensure greater reliability and consistency
- Automated, state-of-the-art, cast-on strap process, Ensures consistent, high-quality, low electrial-resistance welds
- PVC container and cover, Provides excellent water vapor retention, preventing dry out ,prevents oxygen infiltration, High-inpact resistance
- Through-the-partition inter-cell connection, Shortens current paths, Increases performance
- Copper-to-copper connections, Minimize resistance drop, especially at high rates, Reduce need for retoring connections
- Measurable quality and outstanding performance, 100 percent of cells tested for conductance voltage and capacity voltage and cappacity, tested in accordance with Bellcore TR-NWT-000766 specifications , 100 percent of cells tested to 95 percent capacity at the 8-hour rate to 1.75 Vpc
- Comply to SR4228
- UL94 V-0 FR

Liberty 100 Series


Specifications




Model
V
Capacity /Ah
(C10,1.80v@20°c
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L
W
H
TH
LS 12-100 12 100 344 421 174 227 43 Insert
LS 6-200 6 200 688 421 174 227 43 Insert
LS 4-300 4 300 1030 421 174 227 43 Insert
LS 2-600 2 600 2060 421 174 227 43 Insert


HRM Seriers





Vlave Regulated Lead Acid (VRLA)
• 10 years Design life
• 3 years warranty
• For UPS Standby Power Applications

Features:
- 10 year design life @25 °C
- Absorbent Glass Matt (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintence
- 3 year Warranty (refer Dynasty warranty card, 41-9026)
- Patented Long Life Alloy having the lowest calcium levels in the industry , minimizing grid growth , reducing gassing , and battery life
- Patented UL Recognized Flame-arresting vents in each cell for safety and long life
- Proprietary Fixed Orifice Plate Pasting technology applying active materials on both sides of the grid for consistent cell-to-cell performance, higher capacity and uniform grid protection
- Thermally welded case-to-cover bond to eliminate leakage
- Can be operated in any orientation. Upright, side or end mounting recommended


Specifications




Model
V
Watts/Cel @ 15minl
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L/D
W
H
TH
UPS12-100MR
12
100
166
131
162
174
10.0
L-TypeInsert
UPS12-150MR
12
150
197
132
166
173
12.4
Insert(#10-32UNF)
UPS12-210MR
12
210
229
139
200
205
18.0
Insert(#10-32UNF)
UPS12-300MR
12
300
261
173
200
204
26.5
Insert(1/4-20UNC)
UPS12-350MR
12
350
306
173
202
205
30.5
Insert(1/4-20UNC)
UPS12-400MR
12
400
341
173
213
216
34.4
Insert(1/4-20UNC)
UPS12-490MRLP
12
490
341
173
213
216
38.0
Insert(1/4-20UNC)
UPS12-490MR
12
490
345
173
275
278
45.0
Insert(1/4-20UNC)
UPS12-540MR
12
540
345
173
275
278
45.0
Insert(1/4-20UNC)
UPS12-615MRF
12
615
559*
126
273
283
53.0
Front Access(1/4-20UNC)
UPS12-700MRF
12
700
559*
126
310
320
60.0
Front Access(1/4-20UNC)
UPS6-620MR
6
620
321
177
224
227
33.0
Insert(1/4-20UNC)


ms Endur II Series



Valve Regulated Lead Acid (VRLA)
- 20 Years Design Life
- For Wireless Base Stations and Switches, Wire Line Distributed Power Applications
- 7 Years Warranty for Telecom Applications
- 3 Years Full, 12 years Pro-rate Warranty for Switchgear and UPS Float Applications Features:
- Modular Design for ease of installation and stacking flexibillity
- Space saving design for the for the greatest amount of power in a small footprint
- Exceed 1997 UBC Zone 4 seismic requirements
- Certified as NEBS Level 3 and complaint to Earthquake Risk Zone 4 in various system configuarations
- Tin-plated copper alloy connectors minimize maintenance
- New Ohmic Ring for ease of maintenance readings
- Advanced microporous absorbed glass mat separators for ultra-low float current - reduces grid corrosion for a long , usable service life
- Propeitary calcium alloys to minimize positive grid corrosion and growth - maximizes battery life
- Robust polypropylene and cover enhances product quality and improves strength of materials for safe operation with flammability rating UL94V-0,LOI>28%
- Adnvanced formation process results in a narrow float voltage window making onsight float matching unnecessary
- Highly efficient , proprietary processing for high utilization of active material - results in high energy density
- Highly controlled manufacturing processes for exceptional and consistent plate quality
- Proprietary cell design and manufacturing process provides for documented long-lasting service life
- Comply to SR4228


Specifications



Model
V
C8, 1.75V, 25°C (Ah)
C10, 1.80V, 20°C (Ah)
Dimensions (mm)
Terminal Type (Bolt)
L/D
W
H
AT-07P/ATL-07P
2
345/295
330/275
589
79
230
Insert
AT-09P/ATL-07P
2
480/390
460/365
589
98
230
Insert
AT-11P/ATL-11P
2
600/490
575/460
589
116
230
Insert
AT-13P/ATL-13P
2
640/515
610/485
589
116
230
Insert
AT-15P/ATL-15P
2
840/685
800/645
589
155
230
Insert
AT-17P/ATL-17P
2
930/780
875/735
589
155
230
Insert
AT-19P/ATL-19P
2
1080/880
1030/825
589
190
230
Insert
AT-21P/ATL-12P
2
1150/980
1095/920
589
190
230
Insert
AT-23P/ATL-23P
2
1320/1075
1260/1010
589
224
230
Insert
AT-25P/ATL-25P
2
1380/1175
1315/1100
589
224
230
Insert
AT-27P/ATL-27P
2
1560/1270
1490/1195
589
258
230
Insert
AT-29P/ATL-29P
2
1605/1370
1535/1285
589
258
230
Insert
AT-35P/ATL-35P
2
2040/1660
1945/1560
589
339
230
Insert
AT-39P/ATL-39P
2
2180/1855
2085/1745
589
339
230
Insert

TEL Series



Vlave Regulated Lead Acid (VRLA)
• 10 years Design life
• 3 years warranty
• For Telecom Power Applications

Features:
- Flame-arresting one-way pressure-relief vent for safety and long life
- Thermally welded case-to-cover bond to ensure a leak-proof seal
- Flame-reatardent polypropylene case and cover compliant with UL94V-0 with an Oxygen Limiting Index of greater than 28
- Absorbent Glass Mat (AGM) technology for efficient gas recombination 99% plus
- Thick positive plate design for maximum service float life 10 year design life
- Comlpies with UL1778, 924, 1989, and 94V-0
- UL-recognized component
- Can be used in upright, side, or end mounting orientation
- Low-profile terminals with threaded copper alloy inserts dor reduced height, reduced maintenance and increased safety
- Front Access threaded copper alloy inserts on TEL 12-105 F/FS
- Multi-cell design for ease of installation and maintenance
- Comply to SR4228


Specifications



Model
Vot/Unit
C8, 1.75V, 25°C (Ah)
C10, 1.80V, 20°C (Ah)
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L/D
W
H
TEL 12-30*(SLC)
12
30
29.1
197
132
173
12.4
Insert(#10-32UNF)
TEL 12-45*(SLC)
12
46
44.4
228
139
205
18.4
Insert(#10-32UNF)
TEL 12-70
12
69
67.2
261
173
204
25.3
Insert(1/4-20UNC)
TEL 12-80*(SLC)
12
79
77.5
306
173
205
30.2
Insert(1/4-20UNC)
TEL 12-90
12
88
85.5
341
173
216
33.8
Insert(1/4-20UNC)
TEL 12-105F/FS
12
100
98.1
572/558
126
229
38.5
Front Insert(1/4-20UNC)
TEL 12-125
12
126
123
345
173
278
46.4
Insert(1/4-20UNC)
TEL6-180
6
176
171
321
177
227
33.8
Insert(1/4-20UNC)


The True Front Access VRLA




• 13 years life battery
• For Telecom Power Applications

Features:
- Long life alloy and destroy Telecordia certified exceeding 13 years service life
- Tested and qualified by Telecordia to meet SR-4228 requirments
- True Front access threaded copper alloy inserts for reduced maintanance and increased safety
- Terminal versatillity-ease of diagnostic readings with Ohmic Ring
- Reduced headspace driving higher energy density, in cabinet or rack applications
- Innovative front design maximizing energy density with direct with direct connect extrusion fusion weld technology
- Themally welded case-to-cover bond to ensure a leak-proof seal
- Flame-retardent polypropylene case and cover compliant with UL94V-0 with an Oxygen Limiting index of greater than 28
- Absorbent Glass Mat (AGM) technology for efficient gas recombination 99% plus
- Flame-arresting, one -way pressure vent for safety and long life
- Complies with UL1778 , 924 , 1989 and 94 V-0 .BS6290PT4, IEC-896-2
- UL-recognized component
- Multi-cell design dor ease of installation and maintenance


Specifications




Model
Vot/Unit
C8, 1.75V, 25°C (Ah)
C10, 1.80V, 20°C (Ah)
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L/D
W
H
TEL12-105FNSG
12
104
102
410
106
126
32.8
Insert(M8)
TEL12-115FNG
12
108
106
511
110
235
36.0
Insert(M6)
TEL12-145FW
12
145
143
430
163
257
48.0
Insert(M6)
TEL12-155F/FG
12
155
154
559
126
277/283
47.0
Insert(M8)
TEL12-160FW
12
160
153
463
126
257
55.0
Insert(1/4-20UNC)
TEL12-160F
12
157
151
559
126
283
53.0
Insert(1/4-20UNC)
TEL12-170F/FG
12
169
169
559
126
277/283
51.0
Insert(M8)
TEL12-180F
12
181
174
559
126
320
60.0
Insert(1/4-20UNC)
TEL12-190F/FG
12
190
190
559
126
320/326
57.0
Insert(M8)
TEL12-210F/FG
12
202
199
559
126
320/326
60.0
Insert(M8)


BBG/DCS Series




Valve Regulated Lead Acid (VLRA)
• For Broadband Standby Power Applications (BBG)
• For Deep Cycle Mobility Applications (DCS)


Specifications

Model
Volt/ Unit
C20, 1.75V, 25°C (Ah)
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L/D
W
H
TH
BBG-165RT
12
86
318
173
202
230
29
L-Type
BBG-180RT
12
94
341
173
213
216
30
Insert(1/4-20UNC)
BBG-210RT
12
106
341
173
213
216
33
Insert(1/4-20UNC)
DCS-33IT/HIT
12
33
197/207
173
166
173
12
Insert(1/4-20UNC)
DCS-50IT
12
50
229
173
200
205
18
Insert(#10-32UNF)
DCS-75IT/HIT
12
75
261/273
173
200
204
25
Insert(#10-32UNF)
DCS-88HIT
12
88
318
173
202
205
30
Insert(1/4-20UNC)
DCS-100HIT
12
100
341
173
213
216
31
Insert(1/4-20UNC)


OPzS Series




Tubular Flooded
• Design Life : 20 years
• For UPS, Telecom, Solar, Control and Monitoring System Applications

Features:

• Capacity from 100 to 3000 Ah
• Low Maintenance
• Quick and simple acid level control
• Economical water consumption
• Appropriate dimensions and weight
• The lowest and constant maintenance current
• The positive armored plate is of a tubular type. Such construction prevents
escaping of an active substance during the operation and ensures a long
life time
• Excellent cyclic performance
• Translucent plastic containers made of styrenacrylnitril (SAN), which
is extraordinary resistant to chemical influences and mechanical
damage
• Manufactured according to DIN 4073, EN 60896 and IEC 896-1
regulations
• Transparent containers allows visual inspection of electrolyte level
• Well sealed cell plug prevents leakage of an


Specifiactions




Model
Vot/Unit
C8, 1.75V, 25°C (Ah)
C10, 1.80V, 20°C (Ah)
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L/D
W
H
OPzS 12-50
12
6
5
272
205
392
39
Insert(M10)
OPzS 12-100
12
12
10
272
205
392
50
Insert(M10)
OPzS 12-150
12
18
15
380
205
392
69
Insert(M10)
OPzS 6-200
6
24
20
272
205
392
47
Insert(M10)
OPzS 6-250
6
30
26
380
205
392
61
Insert(M10)
OPzS 6-300
6
36
31
380
205
392
68
Insert(M10)
OPzS 2-100
2
13
11
103
206
420
13
Insert(M10)
OPzS 2-150
2
19
16
103
206
420
16
Insert(M10)
OPzS 2-200
2
25
21
103
206
420
18
Insert(M10)
OPzS 2-250
2
31
26
124
206
420
22
Insert(M10)
OPzS 2-300
2
38
31
145
206
536
26
Insert(M10)
OPzS 2-350
2
46
38
124
206
536
29
Insert(M10)
OPzS 2-420
2
55
45
145
206
536
34
Insert(M10)
OPzS 2-490
2
64
53
166
206
536
39
Insert(M10)
OPzS 2-600
2
77
64
145
206
711
50
Insert(M10)
OPzS 2-800
2
103
85
210
191
711
65
Insert(M10)
OPzS 2-1000
2
128
107
210
233
711
80
Insert(M10)
OPzS 2-1200
2
154
128
210
275
711
93
Insert(M10)
OPzS 2-1500
2
198
161
210
275
861
119
Insert(M10)
OPzS 2-2000
2
264
214
212
397
837
160
Insert(M10)
OPzS 2-2500
2
330
268
212
487
837
200
Insert(M10)
OPzS 2-3000
2
398
321
212
576
837
240
Insert(M10)



Flooded Type (Vented)





• Design Life: 20 years
• For Standby Applications
• Nuclear Power Plant(Class 1E)
Features:
- 20-year environmental and seismic qualification (calcium)
- Flame-retardant covers enhance battery plant safety
- Terminals accessible for measurement of individual cell voltages
- Transparent containers allows visual inspectation of plates
- Low-evaporation , flame-arrester vent}
- Electrical testing to 100 percent capacity assures performance of every battery
- Two-point, top-suspended positive plates permit free growth without pressure on jar and cover
- Vacuum-assisted, bottom-pour, positive-grid casting assures plate quality and long life
- Soft rubber post seal minimizes stres on post
- Multi-cell design offers reduced length for optimum space utilization (200Ah or below)
- Fewer bolted connectors per battery string reduce installation and mainentance costs
- Low-maintenace , lead-calcium alloy extends watering intervals
- Snap-on, inter-cell connector covers
- Full capacity range from 25Ah to 4000Ah per single unit
- Wide range of applications; Telecom; UPS; Switchgear & control; Nuclear power plant (Class 1E) and General power plant ; Railway; Oil & Gas
- EP Zone 4 racks avaailable


Specifiactions



Product Series
V
Container Material
Capacity Range(Ah)
Main Applicaitons
Terminal Type
4LCY-C
8
Polycarbonate or San
248 ~ 669
UPS, Switchgear & Control
TOP
4LCY
8
Polycarbonate or San
290 ~ 660
Telecom
TOP
CPV
2
Polypropylene
550 ~ 2600
Renewable Energy Storage
TOP
DCU/DU*
2/6
San
50 ~ 200
Telecom; UPS, Switchgear
TOP
DJ
6
PVC
110 ~ 200
Telecom; UPS, Switchgear
TOP
JC
4/8
Polycarbonate or San
50 ~ 300
Telecom; UPS, Switchgear
TOP
KCR/KAR*
2
Polycarbonate or San
200 ~ 825
UPS, Switchgear & Control
TOP
KCT/KT
2
Polycarbonate or San
270 ~ 720
Telecom
TOP
LCR/LAR*
2
Polycarbonate or San
900 ~ 2320
UPS, Switchgear & Control
TOP
LCT/LT
2
Polycarbonate or San
840 ~ 2320
Telecom
TOP
LCY
2
Polycarbonate or San
2147 ~ 2400
UPS, Switchgear & Control
TOP
LCUN
2
Thermoplastic
1304 ~ 2318
Switchgear & Control
TOP
XDJ
6
Thermoplastic
355 ~ 650 Watt/Cell
UPS
TOP
MCT
2
San / PVC / Polycarb.
3000 ~ 4000
Telecom, Switchgear
TOP
XT
2/4/8
Polycarbonate or San
108 ~ 2600
UPS, Switchgear & Control
TOP
XTHP
2/4/8
Polycarbonate or San
290 ~ 2499
UPS, Switchgear & Control
TOP

 

OPzV Series





Tubular GEL
• Design Life: 15 years
• For Standby & Cyclic Applications

Features:

• Tubular Positive Plate – special grid construction, pressure cast from
antimony free alloy, with highly porous gauntlets that retain the
active material
• Pasted negative plate – service lives consistent with the positive plates
• Separators – extremely high porosity and low internal resistance
• Electrolyte – Gel structure
• Containers and lids – made of plastic (ABS) material. Also
available in ABS flame retardant material as an option
(according to IEC 707 FV0)
• Cells are normally installed in an upright position on steel stands
• One way relief valve – opens at low pressure and is fitted with a
flame arrestor device



Specifiactions





Model
Volt/ Unit
C20, 1.75V, 25°C (Ah)
Dimensions (mm)
Weight/Kg
Terminal Type (Bolt)
L/D
W
H
TH
C&D 2-200T GEL
2
200
103
206
354
380
19
M10
C&D 2-250T GEL
2
250
124
206
354
380
23
M10
C&D 2-300T GEL
2
300
145
206
354
380
28
M10
C&D 2-350T GEL
2
350
124
206
471
496
31
M10
C&D 2-420T GEL
2
420
145
206
471
496
36
M10
C&D 2-490T GEL
2
490
166
206
471
496
41
M10
C&D 2-600T GEL
2
600
145
206
643
668
49
M10
C&D 2-800T GEL
2
800
210
191
664
669
65
M10
C&D 2-1000T GEL
2
1000
210
233
646
671
80
M10
C&D 2-1200T GEL
2
1200
210
275
665
670
93
M10
C&D 2-1500T GEL
2
1500
210
275
796
821
115
M10
C&D 2-2000T GEL
2
2000
214
399
771
796
155
M10
C&D 2-2500T GEL
2
2500
214
487
769
794
200
M10
C&D 2-3000T GEL
2
3000
214
576
771
796
235
M10