Valve Regulated Lead Acid (VRLA) - Design life:10 years |
![]() |
|
Model |
V |
Watts/Cel @ 15minl |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
UPS 12-100 MRX |
12 |
100 |
197 |
132 | 166 | 173 | 10.7 | Insert (#10-32 UNF) |
UPS 12-130 MRX |
12 |
130 |
197 |
132 | 166 | 173 | 11.5 | Insert (#10-32 UNF) |
UPS 12-150 MRX |
12 |
150 |
197 |
132 | 166 | 173 | 12.4 | Insert (#10-32 UNF) |
UPS 12-200 MRX |
12 |
200 |
229 |
139 | 200 | 205 | 17.7 | Insert (#10-32 UNF) |
UPS 12-220 MRX |
12 |
220 |
229 |
139 | 200 | 205 | 19.0 | Insert (#10-32 UNF) |
UPS 12-280R MRX |
12 |
280 |
273 |
174 | 201 | 204 | 25.7 | Insert (1/4-20 UNC) |
UPS 12-320R MRX |
12 |
320 |
273 |
174 | 201 | 204 | 27.0 | Insert (1/4-20 UNC) |
UPS 12-370R MRX |
12 |
370 |
319 |
173 | 203 | 205 | 31.5 | Insert (1/4-20 UNC) |
UPS 12-400 MRX |
12 |
400 |
341 |
173 | 213 | 216 | 35.3 | Insert (1/4-20 UNC) |
UPS 12-440 MRX |
12 |
440 |
341 |
173 | 213 | 216 | 36.0 | Insert (1/4-20 UNC) |
UPS 12-475 MRX |
12 |
475 |
341 |
173 | 213 | 216 | 38.0 | Insert (1/4-20 UNC) |
UPS 12-490 MRX |
12 |
490 |
345 |
173 | 275 | 278 | 46.6 | Insert (1/4-20 UNC) |
UPS 12-520 MRX |
12 |
520 |
345 |
173 | 275 | 278 | 47.2 | Insert (1/4-20 UNC) |
UPS 12-550 MRX |
12 |
550 |
345 |
173 | 275 | 278 | 48.6 | Insert (1/4-20 UNC) |
UPS 12-600 MRX |
12 |
600 |
345 |
173 | 275 | 278 | 49.4 | Insert (1/4-20 UNC) |
- True Front Access threaded copper alloy inserts, for reduced
maintenance and increased safety - Terminal versatility - ease of diagnostic readings with C&D Ohmic Ring® - Innovative front terminal design maximizing energy density with direct connect extrusion fusionweld technology - Reduced headspace driving higher energy density, in cabinet or rack applications - Removable handles for ease of installation - Thermally welded case-to-cover bond to ensure a leak-proof seal - Flame-retardant polypropylene case and cover compliant with UL94 V-0 with an Oxygen Limiting Index of greater than 28 - Absorbent Glass Mat (AGM) technology for efficient gas recombination of over 99% - Flame-arresting, one-way pressure-relief vent for safety and long life - Complies with UL 1778,924,1989 and 94 V-0. BS6290-4, IEC60896 - Multicell design for ease of installation and maintenance |
![]() |
Model |
V |
Watts/Cel @ 15minl |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
UPS 12-410 MRXF |
12 |
410 |
498 |
108 |
215 |
231 |
37.1 |
Insert (M6) |
UPS 12-615 MRXF |
12 |
615 |
547 |
123 |
269 |
278 |
55.2 |
Insert (M8) |
UPS 12-700 MRXF |
12 |
700 |
547 |
123 |
310 |
322 |
64.9 |
Insert (M8) |
Valve Regulated Lead Acid (VRLA) • Design life: 5 years(≤26Ah) Features - Robust plate for extended life- Flame-arresting one-way pressure-relief vent for safety and long life - Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance - UL-recognition component - Multicell design for cost effective installation and maintenance - Can be used in upright, side, or end mounting orientation - Not restricted for air transport Compiles with IATA/ICAO Special Provision - Not restricted for surface transport classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189 - Not restricted to water transport classified as non-hazardous material per IMDG Amendment 27 - Computer designed lead , low Calcium alloy grid for minimal gassing and ease of recycling |
![]() |
Model |
V |
Watts/Cel @ 15minl |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
MPS 12-7A |
12 |
7 |
151 |
65 |
94 |
100 |
2.2 |
Faston Tab 187/250 |
MPS 12-9A |
12 |
9 |
151 |
65 |
94 |
100 |
2.6 |
Faston Tab 187/250 |
MPS 12-12A |
12 |
12 |
151 |
98 |
95 |
101 |
3.6 |
Faston Tab 187/250 |
MPS 12-18A |
12 |
18 |
181 |
77 |
166 |
166 |
5.0 |
Insert (M5) |
MPS 12-26A |
12 |
26 |
166 |
175 |
125 |
125 |
8.1 |
Insert (M5) |
MPS 12-40A |
12 |
40 |
198 |
166 |
171 |
171 |
13.2 |
Insert (M6) |
MPS 12-54 |
12 |
54 |
228 |
139 |
201 |
225 |
17.0 |
L-type (M6) |
MPS 12-65R |
12 |
65 |
273 |
174 |
201 |
224 |
21.0 |
L-type (M6) |
MPS 12-76R |
12 |
76 |
273 |
174 |
201 |
224 |
23.3 |
L-type (M6) |
MPS 12-88R |
12 |
88 |
319 |
173 |
203 |
230 |
25.5 |
L-type (M6) |
MPS 12-100R |
12 |
100 |
319 |
173 |
203 |
230 |
29.0 |
L-type (M6) |
MPS 12-114 |
12 |
114 |
341 |
173 |
213 |
241 |
32.5 |
L-type (M6) |
MPS 12-127A |
12 |
127 |
407 |
177 |
225 |
225 |
35.0 |
Insert (M8) |
MPS 12-158A |
12 |
158 |
483 |
170 |
241 |
241 |
44.5 |
Insert (M8) |
MPS 12-211A |
12 |
211 |
522 |
239 |
218 |
223 |
60.0 |
Insert (M8) |
MPS 12-242A |
12 |
242 |
521 |
269 |
203 |
208 |
67.0 |
Insert (M8) |
Valve Regulated Lead Acid (VRLA) Features : - Lead Calcium Alloy Grids - Lowest Level of Calcium among manufacturers, which reduces grid corrosion - Radial grid design provides the most efficient power pathway to transfer power from the active material to the terminal - Patend Long Life Alloy having the lowest calcium levels in the industry , minimizing grid growth , reducing gassing, and extending battery life - Absorbtion Glass Mat (AGM) technology fo efficient gas recombination of up to 99% and freedom from electrolyte maintenance - Propietary Fixed Orifice Pasting Technology - More consistent pasting process where paste is applied to both sides of the plate to reduce riskof shorts. - Patented UL Recognized Flame-arresting vents in each cell for safety and long life. - Designed with the same rrecombination , thermal runaway prevetion ,gassing and flame retardent characteristics of the Bellcore 4228 - Can be used in upright , side, or end mounting orientation |
- Design life :10 years - 3 years Warranty - For Telecom , UPS, Utility Features - High quality design insurance |
![]() |
Model |
V |
Capacity /Ah |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
C&D 12-25A DNT |
12 |
28 |
151 |
65 |
94 |
100 |
2.2 |
Faston Tab 250 |
C&D 12-65A DNT |
12 |
72 |
181 |
77 |
166 |
166 |
5.6 |
Insert (M5) |
C&D 12-100 DNT |
12 |
100 |
197 |
132 |
166 |
173 |
10.7 |
Insert (#10-32 UNF) |
C&D 12-130 DNT |
12 |
130 |
197 |
132 |
166 |
173 |
11.5 |
Insert (#10-32 UNF) |
C&D 12-150 DNT |
12 |
150 |
197 |
132 |
166 |
173 |
12.4 |
Insert (#10-32 UNF) |
C&D 12-200 DNT |
12 |
200 |
229 |
139 |
200 |
205 |
17.7 |
Insert (#10-32 UNF) |
C&D 12-220 DNT |
12 |
220 |
229 |
139 |
200 |
205 |
19.0 |
Insert (#10-32 UNF) |
C&D 12-280 DNT |
12 |
280 |
273 |
174 |
201 |
204 |
25.7 |
Insert (1/4-20 UNC) |
C&D 12-320 DNT |
12 |
320 |
273 |
174 |
201 |
204 |
27.0 |
Insert (1/4-20 UNC) |
C&D 12-370 DNT |
12 |
370 |
319 |
173 |
203 |
205 |
31.5 |
Insert (1/4-20 UNC) |
C&D 12-400 DNT |
12 |
400 |
341 |
173 |
213 |
216 |
35.3 |
Insert (1/4-20 UNC) |
C&D 12-440 DNT |
12 |
440 |
341 |
173 |
213 |
216 |
36.0 |
Insert (1/4-20 UNC) |
C&D 12-475 DNT |
12 |
475 |
341 |
173 |
213 |
216 |
38.0 |
Insert (1/4-20 UNC) |
C&D 12-490 DNT |
12 |
490 |
345 |
173 |
275 |
278 |
46.6 |
Insert (1/4-20 UNC) |
C&D 12-520 DNT |
12 |
520 |
345 |
173 |
275 |
278 |
47.2 |
Insert (1/4-20 UNC) |
C&D 12-550 DNT |
12 |
550 |
345 |
173 |
275 |
278 |
48.6 |
Insert (1/4-20 UNC) |
C&D 12-600 DNT |
12 |
600 |
345 |
173 |
275 |
278 |
49.4 |
Insert (1/4-20 UNC) |
C&D 12-675A DNT |
12 |
692 |
522 |
239 |
218 |
223 |
65.0 |
Insert (M8) |
C&D 12-775A DNT |
12 |
785 |
522 |
239 |
218 |
223 |
75.5 |
Insert (M8) |
C&D 6-630A DNT |
12 |
630 |
260 |
171 |
220 |
224 |
28.8 |
Insert (M8) |
Valve Regulated Lead Acid (VRLA) • Design life: 10 years Features - Long life alloy and over 10+ years design life (at 25ºC) |
![]() |
Model |
V |
Capacity /Ah (C10,1.80v@25°c |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
C&D 2-200LBT |
2 |
200 |
170 |
106 |
330 |
345 |
12.4 |
Insert (M10) |
C&D 2-300LBT |
2 |
300 |
170 |
150 |
330 |
345 |
17.8 |
Insert (M10) |
C&D 2-400LBT |
2 |
400 |
196 |
171 |
330 |
345 |
23.6 |
Insert (M10) |
C&D 2-500LBT |
2 |
500 |
241 |
171 |
330 |
345 |
29.3 |
Insert (M10) |
C&D 2-600LBT |
2 |
600 |
286 |
171 |
330 |
345 |
35.2 |
Insert (M10) |
C&D 2-800LBT |
2 |
800 |
383 |
171 |
330 |
345 |
47.1 |
Insert (M10) |
C&D 2-1000LBT |
2 |
1000 |
471 |
171 |
330 |
345 |
58.8 |
Insert (M10) |
C&D 2-1500LBT |
2 |
1500 |
476 |
337 |
330 |
345 |
92.0 |
Insert (M10) |
C&D 2-2000LBT |
2 |
2000 |
476 |
337 |
330 |
345 |
117.0 |
Insert (M10) |
C&D 2-2500LBT |
2 |
2500 |
696 |
340 |
330 |
345 |
161.0 |
Insert (M10) |
C&D 2-3000LBT |
2 |
3000 |
696 |
340 |
330 |
345 |
185.0 |
Insert (M10) |
Valve Regulated Lead Acid (VRLA) Features |
![]() |
Model |
V |
Capacity /Ah (C10,1.80v@25°c |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
TEL 12-105FNSG |
12 |
100 |
410 |
107 |
267 |
289 |
33.0 |
Insert (M8) |
TEL 12-115FNG |
12 |
104 |
511 |
110 |
215 |
237 |
33.5 |
Insert (M6) |
TEL 12-155FG |
12 |
148 |
559 |
126 |
269 |
285 |
48.3 |
Insert (M8) |
TEL 12-170FG |
12 |
162 |
559 |
126 |
269 |
285 |
49.5 |
Insert (M8) |
TEL 12-190FG |
12 |
183 |
559 |
126 |
310 |
328 |
57.7 |
Insert (M8) |
TEL 12-210FG |
12 |
195 |
559 |
126 |
310 |
328 |
61.2 |
Insert (M8) |
TEL-FGC Series Features |
![]() |
Design life: 18 years(2V) - Gel electrolyte technology for better wide temperature range performance, prevention from thermal runaway, insure reliability and safety |
![]() |
Model |
V |
Capacity /Ah (C10,1.80v@20°c |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
C&D 2-100 GEL |
2 |
133 |
172 |
102 |
206 |
227 |
8.0 |
Insert (M8) |
C&D 2-150 GEL |
2 |
178 |
173 |
110 |
330 |
366 |
14.0 |
Insert (M8) |
C&D 2-200 GEL |
2 |
222 |
171 |
150 |
330 |
366 |
17.5 |
Insert (M8) |
C&D 2-300 GEL |
2 |
311 |
211 |
176 |
330 |
366 |
24.5 |
Insert (M8) |
C&D 2-400 GEL |
2 |
400 |
242 |
172 |
330 |
366 |
29.0 |
Insert (M8) |
C&D 2-500 GEL |
2 |
533 |
302 |
175 |
330 |
366 |
37.0 |
Insert (M8) |
C&D 2-600 GEL |
2 |
666 |
410 |
175 |
330 |
367 |
46.0 |
Insert (M8) |
C&D 2-800 GEL |
2 |
888 |
475 |
174 |
330 |
366 |
62.0 |
Insert (M8) |
C&D 2-1000 GEL |
2 |
1066 |
475 |
174 |
330 |
366 |
76.0 |
Insert (M8) |
C&D 2-1200 GEL |
2 |
1332 |
401 |
350 |
341 |
383 |
96.0 |
Insert (M8) |
C&D 2-1500 GEL |
2 |
1776 |
490 |
350 |
343 |
383 |
126.5 |
Insert (M8) |
C&D 2-2000 GEL |
2 |
2221 |
710 |
352 |
340 |
383 |
171.0 |
Insert (M8) |
C&D 2-2500 GEL |
2 |
2665 |
710 |
352 |
340 |
383 |
193.0 |
Insert (M8) |
C&D 12-20 GEL |
12 |
23 |
166 |
175 |
125 |
125 |
8.2 |
Insert (M8) |
C&D 12-40 GEL |
12 |
49 |
229 |
138 |
210 |
216 |
18.0 |
Insert (M8) |
C&D 12-50 GEL |
12 |
50 |
260 |
169 |
211 |
216 |
20.5 |
Insert (M8) |
C&D 12-65 GEL |
12 |
67 |
260 |
169 |
211 |
216 |
23.5 |
Insert (M8) |
C&D 12-90 GEL |
12 |
90 |
328 |
172 |
215 |
222 |
30.0 |
Insert (M8) |
C&D 12-100 GEL |
12 |
106 |
407 |
177 |
225 |
225 |
35.0 |
Insert (M8) |
C&D 12-120 GEL |
12 |
119 |
341 |
173 |
281 |
288 |
41.5 |
Insert (M8) |
C&D 12-150 GEL |
12 |
160 |
530 |
209 |
214 |
219 |
53.0 |
Insert (M8) |
C&D 12-180 GEL |
12 |
177 |
522 |
239 |
218 |
223 |
60.0 |
Insert (M8) |
C&D 12-200 GEL |
12 |
204 |
521 |
269 |
203 |
208 |
67.0 |
Insert (M8) |
C&D 12-230 GEL |
12 |
231 |
520 |
268 |
220 |
225 |
74.0 |
Insert (M8) |
Valve Regulated Lead Acid (VRLA) - 10 years life battery Features - Patented C&D post seal design with secondary epoxy to increase integrity |
![]() |
Model |
V |
Capacity /Ah (C10,1.80v@20°c |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L |
W |
H |
TH |
|||||
LS 12-100 | 12 | 100 | 344 | 421 | 174 | 227 | 43 | Insert |
LS 6-200 | 6 | 200 | 688 | 421 | 174 | 227 | 43 | Insert |
LS 4-300 | 4 | 300 | 1030 | 421 | 174 | 227 | 43 | Insert |
LS 2-600 | 2 | 600 | 2060 | 421 | 174 | 227 | 43 | Insert |
Vlave Regulated Lead Acid (VRLA) • 10 years Design life • 3 years warranty • For UPS Standby Power Applications Features: - 10 year design life @25 °C - Absorbent Glass Matt (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintence - 3 year Warranty (refer Dynasty warranty card, 41-9026) - Patented Long Life Alloy having the lowest calcium levels in the industry , minimizing grid growth , reducing gassing , and battery life - Patented UL Recognized Flame-arresting vents in each cell for safety and long life - Proprietary Fixed Orifice Plate Pasting technology applying active materials on both sides of the grid for consistent cell-to-cell performance, higher capacity and uniform grid protection - Thermally welded case-to-cover bond to eliminate leakage - Can be operated in any orientation. Upright, side or end mounting recommended |
Model |
V |
Watts/Cel @ 15minl |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L/D |
W |
H |
TH |
|||||
UPS12-100MR |
12 |
100 |
166 |
131 |
162 |
174 |
10.0 |
L-TypeInsert |
UPS12-150MR |
12 |
150 |
197 |
132 |
166 |
173 |
12.4 |
Insert(#10-32UNF) |
UPS12-210MR |
12 |
210 |
229 |
139 |
200 |
205 |
18.0 |
Insert(#10-32UNF) |
UPS12-300MR |
12 |
300 |
261 |
173 |
200 |
204 |
26.5 |
Insert(1/4-20UNC) |
UPS12-350MR |
12 |
350 |
306 |
173 |
202 |
205 |
30.5 |
Insert(1/4-20UNC) |
UPS12-400MR |
12 |
400 |
341 |
173 |
213 |
216 |
34.4 |
Insert(1/4-20UNC) |
UPS12-490MRLP |
12 |
490 |
341 |
173 |
213 |
216 |
38.0 |
Insert(1/4-20UNC) |
UPS12-490MR |
12 |
490 |
345 |
173 |
275 |
278 |
45.0 |
Insert(1/4-20UNC) |
UPS12-540MR |
12 |
540 |
345 |
173 |
275 |
278 |
45.0 |
Insert(1/4-20UNC) |
UPS12-615MRF |
12 |
615 |
559* |
126 |
273 |
283 |
53.0 |
Front Access(1/4-20UNC) |
UPS12-700MRF |
12 |
700 |
559* |
126 |
310 |
320 |
60.0 |
Front Access(1/4-20UNC) |
UPS6-620MR |
6 |
620 |
321 |
177 |
224 |
227 |
33.0 |
Insert(1/4-20UNC) |
Valve Regulated Lead Acid (VRLA) - 20 Years Design Life - For Wireless Base Stations and Switches, Wire Line Distributed Power Applications - 7 Years Warranty for Telecom Applications - 3 Years Full, 12 years Pro-rate Warranty for Switchgear and UPS Float Applications Features: - Modular Design for ease of installation and stacking flexibillity - Space saving design for the for the greatest amount of power in a small footprint - Exceed 1997 UBC Zone 4 seismic requirements - Certified as NEBS Level 3 and complaint to Earthquake Risk Zone 4 in various system configuarations - Tin-plated copper alloy connectors minimize maintenance - New Ohmic Ring for ease of maintenance readings - Advanced microporous absorbed glass mat separators for ultra-low float current - reduces grid corrosion for a long , usable service life - Propeitary calcium alloys to minimize positive grid corrosion and growth - maximizes battery life - Robust polypropylene and cover enhances product quality and improves strength of materials for safe operation with flammability rating UL94V-0,LOI>28% - Adnvanced formation process results in a narrow float voltage window making onsight float matching unnecessary - Highly efficient , proprietary processing for high utilization of active material - results in high energy density - Highly controlled manufacturing processes for exceptional and consistent plate quality - Proprietary cell design and manufacturing process provides for documented long-lasting service life - Comply to SR4228 |
Model |
V |
C8, 1.75V, 25°C (Ah) |
C10, 1.80V, 20°C (Ah) |
Dimensions (mm) |
Terminal Type (Bolt) |
||||
L/D |
W |
H |
|||||||
AT-07P/ATL-07P |
2 |
345/295 |
330/275 |
589 |
79 |
230 |
Insert |
||
AT-09P/ATL-07P |
2 |
480/390 |
460/365 |
589 |
98 |
230 |
Insert |
||
AT-11P/ATL-11P |
2 |
600/490 |
575/460 |
589 |
116 |
230 |
Insert |
||
AT-13P/ATL-13P |
2 |
640/515 |
610/485 |
589 |
116 |
230 |
Insert |
||
AT-15P/ATL-15P |
2 |
840/685 |
800/645 |
589 |
155 |
230 |
Insert |
||
AT-17P/ATL-17P |
2 |
930/780 |
875/735 |
589 |
155 |
230 |
Insert |
||
AT-19P/ATL-19P |
2 |
1080/880 |
1030/825 |
589 |
190 |
230 |
Insert |
||
AT-21P/ATL-12P |
2 |
1150/980 |
1095/920 |
589 |
190 |
230 |
Insert |
||
AT-23P/ATL-23P |
2 |
1320/1075 |
1260/1010 |
589 |
224 |
230 |
Insert |
||
AT-25P/ATL-25P |
2 |
1380/1175 |
1315/1100 |
589 |
224 |
230 |
Insert |
||
AT-27P/ATL-27P |
2 |
1560/1270 |
1490/1195 |
589 |
258 |
230 |
Insert |
||
AT-29P/ATL-29P |
2 |
1605/1370 |
1535/1285 |
589 |
258 |
230 |
Insert |
||
AT-35P/ATL-35P |
2 |
2040/1660 |
1945/1560 |
589 |
339 |
230 |
Insert |
||
AT-39P/ATL-39P |
2 |
2180/1855 |
2085/1745 |
589 |
339 |
230 |
Insert |
Vlave Regulated Lead Acid (VRLA) • 10 years Design life • 3 years warranty • For Telecom Power Applications Features: - Flame-arresting one-way pressure-relief vent for safety and long life - Thermally welded case-to-cover bond to ensure a leak-proof seal - Flame-reatardent polypropylene case and cover compliant with UL94V-0 with an Oxygen Limiting Index of greater than 28 - Absorbent Glass Mat (AGM) technology for efficient gas recombination 99% plus - Thick positive plate design for maximum service float life 10 year design life - Comlpies with UL1778, 924, 1989, and 94V-0 - UL-recognized component - Can be used in upright, side, or end mounting orientation - Low-profile terminals with threaded copper alloy inserts dor reduced height, reduced maintenance and increased safety - Front Access threaded copper alloy inserts on TEL 12-105 F/FS - Multi-cell design for ease of installation and maintenance - Comply to SR4228 |
Model |
Vot/Unit |
C8, 1.75V, 25°C (Ah) |
C10, 1.80V, 20°C (Ah) |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
||
L/D |
W |
H |
||||||
TEL 12-30*(SLC) |
12 |
30 |
29.1 |
197 |
132 |
173 |
12.4 |
Insert(#10-32UNF) |
TEL 12-45*(SLC) |
12 |
46 |
44.4 |
228 |
139 |
205 |
18.4 |
Insert(#10-32UNF) |
TEL 12-70 |
12 |
69 |
67.2 |
261 |
173 |
204 |
25.3 |
Insert(1/4-20UNC) |
TEL 12-80*(SLC) |
12 |
79 |
77.5 |
306 |
173 |
205 |
30.2 |
Insert(1/4-20UNC) |
TEL 12-90 |
12 |
88 |
85.5 |
341 |
173 |
216 |
33.8 |
Insert(1/4-20UNC) |
TEL 12-105F/FS |
12 |
100 |
98.1 |
572/558 |
126 |
229 |
38.5 |
Front Insert(1/4-20UNC) |
TEL 12-125 |
12 |
126 |
123 |
345 |
173 |
278 |
46.4 |
Insert(1/4-20UNC) |
TEL6-180 |
6 |
176 |
171 |
321 |
177 |
227 |
33.8 |
Insert(1/4-20UNC) |
• 13 years life battery • For Telecom Power Applications Features: - Long life alloy and destroy Telecordia certified exceeding 13 years service life - Tested and qualified by Telecordia to meet SR-4228 requirments - True Front access threaded copper alloy inserts for reduced maintanance and increased safety - Terminal versatillity-ease of diagnostic readings with Ohmic Ring - Reduced headspace driving higher energy density, in cabinet or rack applications - Innovative front design maximizing energy density with direct with direct connect extrusion fusion weld technology - Themally welded case-to-cover bond to ensure a leak-proof seal - Flame-retardent polypropylene case and cover compliant with UL94V-0 with an Oxygen Limiting index of greater than 28 - Absorbent Glass Mat (AGM) technology for efficient gas recombination 99% plus - Flame-arresting, one -way pressure vent for safety and long life - Complies with UL1778 , 924 , 1989 and 94 V-0 .BS6290PT4, IEC-896-2 - UL-recognized component - Multi-cell design dor ease of installation and maintenance |
Model |
Vot/Unit |
C8, 1.75V, 25°C (Ah) |
C10, 1.80V, 20°C (Ah) |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
||
L/D |
W |
H |
||||||
TEL12-105FNSG |
12 |
104 |
102 |
410 |
106 |
126 |
32.8 |
Insert(M8) |
TEL12-115FNG |
12 |
108 |
106 |
511 |
110 |
235 |
36.0 |
Insert(M6) |
TEL12-145FW |
12 |
145 |
143 |
430 |
163 |
257 |
48.0 |
Insert(M6) |
TEL12-155F/FG |
12 |
155 |
154 |
559 |
126 |
277/283 |
47.0 |
Insert(M8) |
TEL12-160FW |
12 |
160 |
153 |
463 |
126 |
257 |
55.0 |
Insert(1/4-20UNC) |
TEL12-160F |
12 |
157 |
151 |
559 |
126 |
283 |
53.0 |
Insert(1/4-20UNC) |
TEL12-170F/FG |
12 |
169 |
169 |
559 |
126 |
277/283 |
51.0 |
Insert(M8) |
TEL12-180F |
12 |
181 |
174 |
559 |
126 |
320 |
60.0 |
Insert(1/4-20UNC) |
TEL12-190F/FG |
12 |
190 |
190 |
559 |
126 |
320/326 |
57.0 |
Insert(M8) |
TEL12-210F/FG |
12 |
202 |
199 |
559 |
126 |
320/326 |
60.0 |
Insert(M8) |
Valve Regulated Lead Acid
(VLRA) • For Broadband Standby Power Applications (BBG) • For Deep Cycle Mobility Applications (DCS) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Tubular Flooded • Design Life : 20 years • For UPS, Telecom, Solar, Control and Monitoring System Applications Features: • Capacity from 100 to 3000 Ah • Low Maintenance • Quick and simple acid level control • Economical water consumption • Appropriate dimensions and weight • The lowest and constant maintenance current • The positive armored plate is of a tubular type. Such construction prevents escaping of an active substance during the operation and ensures a long life time • Excellent cyclic performance • Translucent plastic containers made of styrenacrylnitril (SAN), which is extraordinary resistant to chemical influences and mechanical damage • Manufactured according to DIN 4073, EN 60896 and IEC 896-1 regulations • Transparent containers allows visual inspection of electrolyte level • Well sealed cell plug prevents leakage of an |
Model |
Vot/Unit |
C8, 1.75V, 25°C (Ah) |
C10, 1.80V, 20°C (Ah) |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
||
L/D |
W |
H |
||||||
OPzS 12-50 |
12 |
6 |
5 |
272 |
205 |
392 |
39 |
Insert(M10) |
OPzS 12-100 |
12 |
12 |
10 |
272 |
205 |
392 |
50 |
Insert(M10) |
OPzS 12-150 |
12 |
18 |
15 |
380 |
205 |
392 |
69 |
Insert(M10) |
OPzS 6-200 |
6 |
24 |
20 |
272 |
205 |
392 |
47 |
Insert(M10) |
OPzS 6-250 |
6 |
30 |
26 |
380 |
205 |
392 |
61 |
Insert(M10) |
OPzS 6-300 |
6 |
36 |
31 |
380 |
205 |
392 |
68 |
Insert(M10) |
OPzS 2-100 |
2 |
13 |
11 |
103 |
206 |
420 |
13 |
Insert(M10) |
OPzS 2-150 |
2 |
19 |
16 |
103 |
206 |
420 |
16 |
Insert(M10) |
OPzS 2-200 |
2 |
25 |
21 |
103 |
206 |
420 |
18 |
Insert(M10) |
OPzS 2-250 |
2 |
31 |
26 |
124 |
206 |
420 |
22 |
Insert(M10) |
OPzS 2-300 |
2 |
38 |
31 |
145 |
206 |
536 |
26 |
Insert(M10) |
OPzS 2-350 |
2 |
46 |
38 |
124 |
206 |
536 |
29 |
Insert(M10) |
OPzS 2-420 |
2 |
55 |
45 |
145 |
206 |
536 |
34 |
Insert(M10) |
OPzS 2-490 |
2 |
64 |
53 |
166 |
206 |
536 |
39 |
Insert(M10) |
OPzS 2-600 |
2 |
77 |
64 |
145 |
206 |
711 |
50 |
Insert(M10) |
OPzS 2-800 |
2 |
103 |
85 |
210 |
191 |
711 |
65 |
Insert(M10) |
OPzS 2-1000 |
2 |
128 |
107 |
210 |
233 |
711 |
80 |
Insert(M10) |
OPzS 2-1200 |
2 |
154 |
128 |
210 |
275 |
711 |
93 |
Insert(M10) |
OPzS 2-1500 |
2 |
198 |
161 |
210 |
275 |
861 |
119 |
Insert(M10) |
OPzS 2-2000 |
2 |
264 |
214 |
212 |
397 |
837 |
160 |
Insert(M10) |
OPzS 2-2500 |
2 |
330 |
268 |
212 |
487 |
837 |
200 |
Insert(M10) |
OPzS 2-3000 |
2 |
398 |
321 |
212 |
576 |
837 |
240 |
Insert(M10) |
• Design Life: 20 years • For Standby Applications • Nuclear Power Plant(Class 1E) Features: - 20-year environmental and seismic qualification (calcium) - Flame-retardant covers enhance battery plant safety - Terminals accessible for measurement of individual cell voltages - Transparent containers allows visual inspectation of plates - Low-evaporation , flame-arrester vent} - Electrical testing to 100 percent capacity assures performance of every battery - Two-point, top-suspended positive plates permit free growth without pressure on jar and cover - Vacuum-assisted, bottom-pour, positive-grid casting assures plate quality and long life - Soft rubber post seal minimizes stres on post - Multi-cell design offers reduced length for optimum space utilization (200Ah or below) - Fewer bolted connectors per battery string reduce installation and mainentance costs - Low-maintenace , lead-calcium alloy extends watering intervals - Snap-on, inter-cell connector covers - Full capacity range from 25Ah to 4000Ah per single unit - Wide range of applications; Telecom; UPS; Switchgear & control; Nuclear power plant (Class 1E) and General power plant ; Railway; Oil & Gas - EP Zone 4 racks avaailable |
Product Series |
V |
Container Material |
Capacity Range(Ah) |
Main Applicaitons |
Terminal Type |
4LCY-C |
8 |
Polycarbonate or San |
248 ~ 669 |
UPS, Switchgear & Control |
TOP |
4LCY |
8 |
Polycarbonate or San |
290 ~ 660 |
Telecom |
TOP |
CPV |
2 |
Polypropylene |
550 ~ 2600 |
Renewable Energy Storage |
TOP |
DCU/DU* |
2/6 |
San |
50 ~ 200 |
Telecom; UPS, Switchgear |
TOP |
DJ |
6 |
PVC |
110 ~ 200 |
Telecom; UPS, Switchgear |
TOP |
JC |
4/8 |
Polycarbonate or San |
50 ~ 300 |
Telecom; UPS, Switchgear |
TOP |
KCR/KAR* |
2 |
Polycarbonate or San |
200 ~ 825 |
UPS, Switchgear & Control |
TOP |
KCT/KT |
2 |
Polycarbonate or San |
270 ~ 720 |
Telecom |
TOP |
LCR/LAR* |
2 |
Polycarbonate or San |
900 ~ 2320 |
UPS, Switchgear & Control |
TOP |
LCT/LT |
2 |
Polycarbonate or San |
840 ~ 2320 |
Telecom |
TOP |
LCY |
2 |
Polycarbonate or San |
2147 ~ 2400 |
UPS, Switchgear & Control |
TOP |
LCUN |
2 |
Thermoplastic |
1304 ~ 2318 |
Switchgear & Control |
TOP |
XDJ |
6 |
Thermoplastic |
355 ~ 650 Watt/Cell |
UPS |
TOP |
MCT |
2 |
San / PVC / Polycarb. |
3000 ~ 4000 |
Telecom, Switchgear |
TOP |
XT |
2/4/8 |
Polycarbonate or San |
108 ~ 2600 |
UPS, Switchgear & Control |
TOP |
XTHP |
2/4/8 |
Polycarbonate or San |
290 ~ 2499 |
UPS, Switchgear & Control |
TOP |
Tubular GEL • Design Life: 15 years • For Standby & Cyclic Applications Features: • Tubular Positive Plate – special grid construction, pressure cast from antimony free alloy, with highly porous gauntlets that retain the active material • Pasted negative plate – service lives consistent with the positive plates • Separators – extremely high porosity and low internal resistance • Electrolyte – Gel structure • Containers and lids – made of plastic (ABS) material. Also available in ABS flame retardant material as an option (according to IEC 707 FV0) • Cells are normally installed in an upright position on steel stands • One way relief valve – opens at low pressure and is fitted with a flame arrestor device |
Model |
Volt/ Unit |
C20, 1.75V, 25°C (Ah) |
Dimensions (mm) |
Weight/Kg |
Terminal Type (Bolt) |
|||
L/D |
W |
H |
TH |
|||||
C&D 2-200T GEL |
2 |
200 |
103 |
206 |
354 |
380 |
19 |
M10 |
C&D 2-250T GEL |
2 |
250 |
124 |
206 |
354 |
380 |
23 |
M10 |
C&D 2-300T GEL |
2 |
300 |
145 |
206 |
354 |
380 |
28 |
M10 |
C&D 2-350T GEL |
2 |
350 |
124 |
206 |
471 |
496 |
31 |
M10 |
C&D 2-420T GEL |
2 |
420 |
145 |
206 |
471 |
496 |
36 |
M10 |
C&D 2-490T GEL |
2 |
490 |
166 |
206 |
471 |
496 |
41 |
M10 |
C&D 2-600T GEL |
2 |
600 |
145 |
206 |
643 |
668 |
49 |
M10 |
C&D 2-800T GEL |
2 |
800 |
210 |
191 |
664 |
669 |
65 |
M10 |
C&D 2-1000T GEL |
2 |
1000 |
210 |
233 |
646 |
671 |
80 |
M10 |
C&D 2-1200T GEL |
2 |
1200 |
210 |
275 |
665 |
670 |
93 |
M10 |
C&D 2-1500T GEL |
2 |
1500 |
210 |
275 |
796 |
821 |
115 |
M10 |
C&D 2-2000T GEL |
2 |
2000 |
214 |
399 |
771 |
796 |
155 |
M10 |
C&D 2-2500T GEL |
2 |
2500 |
214 |
487 |
769 |
794 |
200 |
M10 |
C&D 2-3000T GEL |
2 |
3000 |
214 |
576 |
771 |
796 |
235 |
M10 |