DPA UPScale RI DPA UPScale ST
dpa-upscale-ri dpa-upscale-st
Rack Indipendent
(RI)RI 10-80 kW up to 4 Modules
Standard (ST)
ST 10 –120 kW up to 6 Modules

 

The Fundamental Pylons of DPA UPScale

DPA UPScaleTMST 120 kW
dpa-upscale-tmst-120kw

 

DPA UPScaleTM: Essential questions :
  • Is a double conversion , true on-line UPS essential for you?
  • Is a decentralized UPS control important for you?
  • Is a small or smallest foot print important for you?
  • Is efficiency important to you?
  • Is future power expansion without extra installation important for you?
  • Is the module and UPS weight an importantfeature for you?
  • Do you appreciate having individual displays for each module ?
  • Is it a benefit for you having just one person (instead of two) to replace or add a module ?
  • Is front access compulsary ?
  • Having flexible battery block no. for better sizing of autonomy times. Is this important for you ?
  • Having a separate battery for each individual module increases the overall availability as opposed to a common battery. Is this important for you ?
  • Having a variety of cabinets increases the flexibility of choice. Is this a benefit for you ?
  • How important is the efficiency and TCO for you ?

 

True On-line Transformerless -Topology

Normal Operation

  • Full double conversion Technolgy
  • Transformerless ; Totel Efficiency up to 95.5 %
  • Output DC offsets full under control through EDCP
  • Highest output performance
  • Lowest Input distortion through IGBT Booster/Rectifier

 

 

Decentralized Parallel Architecture DPA

Decentralized Parallel Architecture (DPA)TM from NEWAVE

Decentralized Parallel Architecture (DPA)TMwas designed to distribute virtually the entire UPS Hardware and Software into modules in order to reduce the Single Points of Failures (SPOF). DPA includes distributed.

  • Control Panel on Module
  • CPU
  • Power Unit
  • Static bypass switch
    and
  • Separate BATTERIES & RECTIFIERS

DPA UPScaleTM HIGHLIGHTS and Benefits

  • High level of decentralization
  • Multi Master and Slave Technology through a simplified BUS Communication
  • Full redundancy on inverter
  • Full redundency on Static Bypass Switch (SBS)

DPA UPScaleTM / Environmental Friendly

Reduced TCO

Input Power Factor versus load

Advanced Booster PFC circuit to provide near-unity Input PF even with partial loads.

Benefits:

  • No phase compensation filter required
  • Respect power grid regulations
  • Energy savings

DPA UPScaleTM / Environmental Friendly

Reduced TCO

Input THDi versus load

Advanced Booster PFC circuit to provide Flat THDI Curve even with partial loads..

Benefits:

  • No gen-set oversized required
  • Small cable/fuses/breakers size
  • No extra heating of transformers

UNIQUE ELECTRICAL PERFORMANCE

 

DPA UPScaleTM / Energy Saving

Reduced TCO

Input THDi versus load

Results in low losses at PARTIAL and FULL load.Redundant UPS Systems operate typically at 25-75% of the rated load.

Energy Saving…

Highlights

  • Safe-Swap Modules
  • High Availability
  • Enhanced Serviceability
  • Flexibility / Scalability
  • Low Cost of Ownership thanks to right sizing
  • Lowest Module weight in its class
  • Blade Server Friendly Power/Leading loads
  • High Power Density
  • Reduced Footprint

 

 

Safe-SwapModular Architecture

Safe-swap, is a term used to refer to hot insertion and removal of modules from a host system without removing power.

In a redundant Power Protection System Safe-swap is achieved only if a faulty module may be replaced without interrupting the power to the load (application) and w/o having to transfer the load (application) to the raw mains (by-pass).

Employing appropriate hot swap techniques highly available power protection systems with ease of scaling and easy fault recovery can be created.

 

Safe-Swap modules

The DPA UPScaleTMModules are fully independent and are composed of all major hardware and firmware building blocks:

  • CPU (Central Processing Unit)
  • All power circuits (rectifier, inverter, battery charger)
  • Static switch and static switch control
  • Power Management Control Panel

 

 

back to top

 

High Availability

To achieve near-zero downtime and avoid very costly consequences of disruption of Mission Critical Applications, advanced Modular Power Protection Architectures with High Availability must be employed.

 

 

Enhanced Serviceability

  • Safe-Swap Modular design, minimize service and maintenance costs
  • One person can easaly exchange the low weight modules
  • MTTR reduction maximize your power protection availability
  • No need of skilled personnel on site
  • Non need of spares, only modules for an easy fault recovery

 

 

DPA UPScaleTMPower Range 10-120 kW

2 module 3 modules 4 modules 6 modules
UPScale ST 40 UPScale ST 60 UPScale ST 80 UPScale ST 120
upscale-st-40 upscale-st-60 upscale-st-80 upscale-st-120
WxHxD 550x1135x767
2 x 40 x 7.2/9Ah
Total 80 blocks
WxHxD 550x1975x757
3 x (2x40) x 7.2/9Ah
Total 240 blocks
WxHxD 550x1135x767
External Batt. ONLY
WxHxD 550x1975x767
External Batt. ONLY

 

 

DPA

UPScale RI 10 UPScale RI 11 UPScale RI 12
upscale-ri-10 upscale-ri-11 upscale-ri-12
WxHxD 488x487x732
(11Hu)
WxHxD 488x487x732
(11Hu)
WxHxD 488x665x732
(15HU)
No internal BATTERIES & RECTIFIERS 1 x 40 x 7.2/9Ah
Total 40 blocks
2x40 x 7.2/9Ah
Total 80 blocks

UPScaleTMRI 10-80 kWRack-Independent Models

 

 

DPA UPScaleTMRI 10-80 kWRack-Independent Models

UPScale RI 20 UPScale RI 22 UPScale RI 24 UPScale RI 40
upscale-ri-20 upscale-ri-22 upscale-ri-24 upscale-ri-40
WxHxD 488x665x732
(15HU)
WxHxD 488x798x732
(18HU)
WxHxD 488x1153x732
(26HU)
WxHxD 488x798x732
(18HU)
No internal Battery 2x40 x 7.2/9Ah
Total 80 blocks
4x40 x 7.2/9Ah
Total 160 blocks
No internal Battery

 

 

Rightsizing Over Time

 

 

Blade Server Frinedly Power

Blade Servers have leading Power Factors and therefore require adequate power from UPS

 

DPA UPScale provides full rated power in KW @ cosphi 1

or constant KVA rating from -0.90 lead. to 0.60 lag.

 

 

Features:DPA UPScale ST10-120 kW

  • DPA with Safe-Swap Modules (SSM)
  • Exceptionally low Module weight
  • Safe Swap extendable from 10-120kW (max. 6 Modules)
  • Flexible battery management blocks
  • Ripple free through battery charger
  • Distributed control and power
  • LCD display integrated on Module
  • Low Total Cost of Ownership (TCO)
  • Huge Flexibility / Scalability
  • Easy to install and service
  • Excellent Input PFC: >0.99 @ 100% load
  • Low input THDI: < 3% @ 100% load
  • High conversion efficiency: up to 95.5%

 

 

Features:DPA UPScale RI10-80 kW

  • Integratable in any 19” rack
  • DPA with Safe-Swap Modules (SSM)
  • Exceptionally low Module weight
  • Safe Swap extendable from 10-80 kW (4 Modules)
  • Flexible battery management blocks
  • Ripple free through battery charger
  • Distributed control and power
  • LCD display integrated on Module
  • Huge Flexibility / Scalability
  • Easy to install and service
  • Excellent Input PFC: >0.99 @ 100% load
  • Low input THDI: < 3% @ 100% load
  • High conversion efficiency: up to 95.5%

 

 

DPA UPScaleTMST 10-120 kW

FEATURES Todays BENEFITS
Reduced weight
(10kW =18.3kg, 20kW=21.5kg)
Ease of handling ONE Technicians
(Ease of Maintenance and Service)
High Power Density
(272kW / m2)
Small foot-print
(Expensive floor-space saving)
Unity Input PF=0.99
(Flat PF curve)
Reduced size of Cables and Fuses
(Installation Cost Saving)
Input THD i = < 3%
(Flat THD i curve)
Reduced Harmonic Injection to Mains
(No need for GENSET over-sizing)
Unity Output PF (KW)
(Optimize Power @ cosphi 1.0)
Blade Server –Friendly Technology
(No need for UPS Power Derating @ cosphi 1)
High Efficiency
(Flat Efficiency Curve)
Energy Saving
(Reduced Losses and Cooling Energy)

 

 

DPA UPScaleTMBusiness Value of Power Protection

With the modular, safe swap UPS systems, you can build your own IT-Facility to meet simultaneously and most accurately:

  1. Higher Availability
  2. Unmatched flexibility to changes
  3. Reduced footprint
  4. Lowest TCO
  5. Product standardization

 