STAND ALONE UPS SYSTEMS

MODULAR UPS SYSTEMS

BATTERIES & RECTIFIERS


SOLAR PRODUCTS


POWERVARIO

 

Intelligent True On-Line Uninterruptible Power Supply (UPS)

Technical specifications

MODEL PVO11/1K PVO11/2K PVO11/3K PVO11S/2K PVO11S/3K
Apparent Output Power 1000 VA 2000 VA 3000 VA 2000 VA 3000 VA
Active Output Power 700 watts 1400 watts 2100 watts 1600 watts 2400 watts
Autonomous Time (Standard Battery) 7 min. 7 min. 6 min. 6 min. 5 min.
Power Factor 0.7 0.7 0.7 0.8 0.8
Topology Double conversion online VFI-SS-111
Type Rack/tower
INPUT
Nominal Voltage 160-288 VAC
Frequency 50/60 Hz, autoselect, ±5 Hz
Power Factor ±0.99 at full rated linear load
Input Current Total Harmonic Distortion THDi < 6% at 100% linear load
OUTPUT
Voltage Adjustable to 220/230/240 VAC
Frequency 50/60 Hz, autoselect synchronisation window, 3 Hz or 1 Hz (setting via software)
Total Harmonic Distortion THD ±3% THD (linear load), ±7% THD (non-linear load)
Overloading Capability Inverter mode: 120% for 20 seconds, bypass mode: 175% for 1 second
Crest Factor 3:1
EFFICIENCY
Load 100/75/50/25% 85/82/82/80 85/82/82/80 88/85/85/83 92/88/84/80 89/88/85/83
ENVIRONMENT
Storage Temperature/Operating Temperature (°C) 0-45/0-40
COMMUNICATIONS
Interfaces RS-232, USB, SNMP card (option), modbus card (option), relay card (option)
DIMENSIONS, WEIGHT
Dimensions H x W x D (mm) 89 x 445 x 490 89 x 445 x 660 89 x 445 x 660 177 x 445 x 420 177 x 445 x 420
Weight (kg) 17 30 33 27 30
OPTIONS
Accessories External bypass, additional battery packs, output distributions, 19" pull-out rack rails
STANDARDS
Safety EN 62040-1-1, IEC 60950-1
Electromagnetic Compatibility (EMC) EN 62040-2, EN 61000-3-2, EN 61000-3-3, FCC Class A
Performance
EN 62040-3
Product Certification CE, cUL, FCC, additional versions on request
Enclosure
IP 20
Manufacture Certified to ISO 9001:2000

 

MODEL PVO11/4.5K PVO11/6K PVO11S/6K PVO11/8/K PVO11/10K
Apparent Output Power 4500 VA 6000 VA 6000 VA 8000 VA 10000 VA
Active Output Power 3250 watts 4200 watts 4800 watts 6400 watts 8000 watts
Autonomous Time (Standard Battery) 10 min. 8 min. 6 min. 7 min. 5 min.
Power Factor 0.7 0.7 0.8 0.8 0.8
Topology Double conversion online VFI-SS-111
Type Rack/tower
INPUT
Nominal Voltage 160-280 VAC
Frequency 50/60 Hz, autoselect, ±5 Hz
Power Factor ±0.99 at full rated linear load
Input Current Total Harmonic Distortion THDi < 6% at 100% linear load
OUTPUT
Voltage Adjustable to 220/230/240 VAC
Frequency 50/60 Hz, autoselect synchronisation window, 3 Hz or 1 Hz (setting via software)
Total Harmonic Distortion THD ±3% THD (linear load), ±7% THD (non-linear load)
Overloading Capability Inverter mode: 120% for 20 seconds, bypass mode: 175% for 1 second
Crest Factor 3:1
EFFICIENCY
Load 100/75/50/25% 92/89/89/87 92/89/89/87 91/89/89/85 91/91/91/89 91/91/91/89
ENVIRONMENT
Storage Temperature/Operating Temperature (°C) 0-45/0-40
COMMUNICATIONS
Interfaces RS-232, USB, SNMP card (option), modbus card (option), relay card (option)
DIMENSIONS, WEIGHT
Dimensions H x W x D (mm) 222 x 445 x 660 222 x 445 x 660 309 x 445 x 580 264 x 445 x 680 264 x 445 x 680
Weight (kg) 92 92 96 96 96
OPTIONS
Accessories External bypass, additional battery packs, output distributions, 19" pull-out rack rails
STANDARDS
Safety EN 62040-1-1, IEC 60950-1
Electromagnetic Compatibility (EMC) EN 62040-2, EN 61000-3-2, EN 61000-3-3, FCC Class A
Performance
EN 62040-3
Product Certification CE, cUL, FCC, additional versions on request
Enclosure
IP 20
Manufacture Certified to ISO 9001:2000

 

back to top

The multifunctional UPS solution

 

PowerVario is a multifunctional UPS series for single-phase uninterruptible power supply for server, network, storage, VolP and telecommunication applications.

The UPS can be used as a stand-alone or 19" rack configuration with Newave connectivity options. It is the perfect solution for mission critical applications which require high reliability, availability and performance.

The UPS completely regenerates the utility power to correct power disturbances in the mains. The unit provides clean AC power with Voltage and Frequency Independency from the mains power supply (VFI).

PowerVario provides an excellent return on your investment. The system is fully modular and allows you to increase the overall power output, battery run-time and redundancy as your needs and requirements grow. The modular design eliminates any single point of failure.

  • Compact design
  • Combined 19" rack and tower version
  • 4.5 kVA and 6 kVA can be connected for parallel redundancy
  • Interfaces: USB, RS-232, SNMP, modbus,potential free contacts, EPO contact inputs

PowerVario enables integration into
a wide variety of environments

 

PowerVario innovations

  • Outlets switchable via software or Web browser
  • Frequency converter adjustable
  • Eco mode function adjustable

 

Hot-swappable BATTERIES & RECTIFIERS

PowerVario 3 kVA with front access for battery swap. PowerVario allows the user to easily replace the battery packs without interrupting the critical load.

Advanced battery discharge management

The PowerVario UPS series automatically manages the end-discharge voltage of the internal BATTERIES & RECTIFIERS according to the load. The ABDM function prevents deep discharge of the BATTERIES & RECTIFIERS during a power failure. Only 4U high with additional battery extension.

 

Optional and additional battery modules

PowerVario 3 kVA with optional and additional battery modules for extended battery run-time. Only 4U high with additional battery extension.

High output performance

PowerVario 4.5 -10 kVA with standard battery module. 4.5 and 6 kVA with a latchable safe-swap connector for the shortest possible MTTR.

Parallel redundancy

To increase the power capacity when configuring a parallel redundant system, up to three PowerVario systems are simply interconnected using the CAN-bus (RJ45) on the rear of the PowerVario series. Option: ParaDis, a combined service bypass and distributor for 4.5 and 6 kVA. Versions are available for 1, 2 or 3 x UPS to create a 1+1 or 2+1 redundancy with safe-swap connection.

User-friendly display

An easy-to-read display provides a real-time view of all major system parameters and the system status, including load level, battery level, system wiring faults, overload, programmable output status, etc.

Options

1, 2 and 3 kVA service bypass with output distribution and fuses – short MTTR.

19" power distribution

PVO-PDM32

Optional flexible rack rails (for many rack manufacturers)

Optional SNMP/modbus network interface cards (dry contacts also available)

Latchable input/output connector to UPS for safe-swap

 

back to top