STAND ALONE UPS SYSTEMS

MODULAR UPS SYSTEMS

BATTERIES & RECTIFIERS


SOLAR PRODUCTS


PowerWave 33

Contents


  • The range
  • The performances
  • Options
  • Additional info

Unmatched Power Performances

The full range


Technology: On-Line, transformer less
Power range: 60-80-100-120-160-200-250-300-400-500 kVA/kW (3/3)
Rated at PF = 1

 

The range with battery enclosures


Power range: 60-80-100 kVA/kW (3/3)
Rated at PF = 0.9

  • Design
  • Compactness
  • Type of ventilation
  • Battery’s enclosures and enhancement
  • Input electrical performances
  • Unmatched power performances
  • Efficiency
  • Full output active power kVA=kW

Back to top

The Design of PowerWave 33

Mix & Match Data Centre & technical room environment

 

Back to top

 

The compactness of PowerWave 33


60-80-100kW
550 x 1820 x 750 mm
From 230 to 245kg
FEATURES
  • Compact size
  • Low weight
  • Full front access only
60-80-100kW with BAT-ENC A
970 x 1820 x 750 mm
From 250 to 285 kg (w/o batt.)

BENEFITS

  • Space costs savings
  • Less transportation costs
  • No need for special floor basement
  • No rear access needed
60-80-100kW with BAT-ENC B
1180 x 1820 x 750 mm
From 270 to 305 kg (w/o batt.)
 
120-160-200kW
850 x 1820 x 750 mm
From 280 to 310kg
FEATURES
  • Compact size
  • Low weight
  • Full front access only
250 x 300 kW
1100x 1920 x 750 mm
From 390 to 410 kg

BENEFITS

  • Space costs savings
  • Less transportation costs
  • No need for special floor basement
  • No rear access needed
  • 400-500kVA can be placed against the wall
400-500 kW
1650 x 1994 x 850 mm
From 950 to 1000 kg
 

 

The ventilation of PowerWave 33


60-300kW : front - rear 400-500 kW : front - top

 

The battery’s enclosures and chargers


Battery chargers

  • 60-100kW: 25A battery charger
  • 120-200kW: 50A battery charger
  • 250-300kW: 60A battery charger
  • 400-500kW: 100A battery charger

 

Back to top

Battery’s enhancement


FEATURES

Allowable battery blocks at full power

  • 60-160kW: from 44 to 50 battery blocks
  • 200kW: 50 battery Blocks
  • 250-300kW: from 44 to 50 battery blocks
  • 400-500kW: from 44 to 50 battery blocks

 

Ripple free through battery charger

No battery operation during load jump
Battery temp. compensation (option)

BENEFITS

Flexibility for autonomy rating

Increase of battery life expectancy

 

 

Input electrical performances


FEATURES

Wide input voltage range:

300-460V @ 100 % load (-25%/+15%)
 280-460V @   80% load  (-30%/+15%)
 240-460V @ <60 % load (-40%/+15%)

Wide input frequency range:

 35–70 Hz

BENEFITS

Less need for battery operation Increase of battery expectance life

FEATURES

  • Improved input PFC:
    >0.99 @ 100% load
  • Low input THDI:
    <3.5% @ 100% load

BENEFITS

  • Smaller cables and fuse size
  • No phase compensation device required
  • No malfuntion and false tripping
  • No extra heating losses in transformers
  • No gen-set oversized
  • Longer plant life

  • Less energy costs

 

Unmatched power performance Efficiency


FEATURES

Best in class efficiency:

  • up to 96% in on-line mode
  • Up to 99% in eco-mode

BENEFITS

Energy bill savings
Air conditioning cost savings
Reduced TCO

 

The efficiency of PowerWave 33


Do not look only at the initial costs but consider the operating ones for ROI calculation

Difference in efficiency

2%

3%

4%

Load (kW)

5 years

10 years

5 years

10 years

5 years

10 years

100

13’734

27’469

20’825

41’649

28’069

56’139

500

68’673

137’346

104’123

208’247

140’348

280’696

1000

137’346

274’693

208’247

416’493

280’697

561’394

 

COST SAVINGS (Euros)

  • kWh cost = 0.10 Euro
  • Cooling factor = 0.4

Unmatched power performance Full output active power kVA=kW


FEATURES

Voltage tolerance:

  • THDU < 2% with linear load
  • THDU < 3% with non-linear load

Voltage regulation:

  • Static +/-1%
  • Dynamic +/-4%

Rated up to a power factor = 1

BENEFITS

Excellent voltage quality/stability
Compatible with all loads (blade servers) without de-rating

 

Back to top

 

Master your power


≥ 44 batt. blocks (except 200kVA only 50 blocks)
11% more active power than UPS rated at 0.9
25% more active power than UPS rated at 0.8

 

Back to top

 

Parallelability (optional)


  • Up to 10 UPS in DPA parallel configuration
  • Parallel Kit factory mounted only
  • Synchronisation Kit (only if equipped with parallel kit and only factory mounted)

 

Options


Available and structured options

  • Back feed protection
  • Parallel kit (one additional PCB + one parallel adapter)
  • Parallel cables with different lenghts
  • Synchronization kit (available only with parallel kit)
  • Connectivity (SNMP,Multidrop,etc.)
  • Elevation kit
  • Manual by-pass switch (only for 400-500kVA)

On request


  • I/O transformers
  • IP 21 Protection (60-300kW only)

400-500kVA front view


Certificate

  • Electrosuisse certificate
  • Newave will get a performance certificate from ElectroSuisse for a 100–200–300-500kVA (independent institute comparable to TŰV)

Back to top